File:Synaptic-vesicles-are-primed-for-fast-clathrin-mediated-endocytosis-at-the-ribbon-synapse-Video2.ogv
From Wikimedia Commons, the free media repository
Jump to navigation
Jump to search
No higher resolution available.
Synaptic-vesicles-are-primed-for-fast-clathrin-mediated-endocytosis-at-the-ribbon-synapse-Video2.ogv (Ogg Theora video file, length 7.0 s, 256 × 256 pixels, 372 kbps, file size: 316 KB)
File information
Structured data
Captions
Summary
[edit]DescriptionSynaptic-vesicles-are-primed-for-fast-clathrin-mediated-endocytosis-at-the-ribbon-synapse-Video2.ogv |
English: Dynamics of clathrin LCa-EGFP around active zone. The same footprint as in Supplementary Movie 1, but the signal in the green channel represents the relative change in the fluorescence, with black at ΔF/F = 0, and saturation at ΔF/F = 0.6 (corresponding to Figure 3B). Note the transient appearance of clathrin LCa-EGFP around several (but not all) ribbons. |
||
Date | |||
Source | Supplementary Movie 2 from Pelassa I, Zhao C, Pasche M, Odermatt B, Lagnado L (2014). "Synaptic vesicles are “primed” for fast clathrin-mediated endocytosis at the ribbon synapse". Frontiers in Molecular Neuroscience. DOI:10.3389/fnmol.2014.00091. PMID 25520613. PMC: 4248811. | ||
Author | Pelassa I, Zhao C, Pasche M, Odermatt B, Lagnado L | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 4.0 International license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 03:29, 21 December 2014 | 7.0 s, 256 × 256 (316 KB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Author | Pelassa I, Zhao C, Pasche M, Odermatt B, Lagnado L |
---|---|
Usage terms | http://creativecommons.org/licenses/by/4.0/ |
Image title | Dynamics of clathrin LCa-EGFP around active zone. The same footprint as in Supplementary Movie 1, but the signal in the green channel represents the relative change in the fluorescence, with black at ΔF/F |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2014-12-01 |