File:Penetration sizing.jpg

From Wikimedia Commons, the free media repository
Jump to navigation Jump to search

Original file (551 × 763 pixels, file size: 276 KB, MIME type: image/jpeg)

Captions

Captions

Add a one-line explanation of what this file represents

Summary

[edit]
Description This drawing is intended to illustrate common guidelines for the forming of through-penetrations such that proper sizing and costing for firestops can occur. In the case of sleeving, which is limited to fire-separations made of concrete and masonry, the mechanical and electrical trades are responsible for the sizing of the openings because they apply the sleeves. In the case of drywall fire separations, the opening size is determined by the drywall contractor, unless the mechanical and electrical trades are contractually obliged to provide sleeving here as well, with proper fastening methods that must be subject to bounding. All trades shall can use this guideline. This permits accurate priceing as well as accountability for field variances. Exceptions are penetrations in timber floors. Often, timber floor openings are simply cut by means of a chainsaw. In this case, the width of the blade will determine sizes. Sizing of all openings has significant impact upon bounding. Therefore, communication between all affected trades is of great importance before any openings are made.
Date
Source Own work
Author Achim Hering

Licensing

[edit]
I, the copyright holder of this work, hereby publish it under the following license:
w:en:Creative Commons
attribution share alike
This file is licensed under the Creative Commons Attribution-Share Alike 3.0 Unported license.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
  • share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the same or compatible license as the original.
This diagram image could be re-created using vector graphics as an SVG file. This has several advantages; see Commons:Media for cleanup for more information. If an SVG form of this image is available, please upload it and afterwards replace this template with {{vector version available|new image name}}.


It is recommended to name the SVG file “Penetration sizing.svg”—then the template Vector version available (or Vva) does not need the new image name parameter.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current16:22, 1 October 2007Thumbnail for version as of 16:22, 1 October 2007551 × 763 (276 KB)Achim Hering (talk | contribs){{Information |Description=This drawing is intended to illustrate common guidelines for the forming of through-penetrations such that proper sizing and costing for firestops can occur. In the case of sleeving, which is limited to fire-separations made

The following 2 pages use this file:

Metadata