[edit]DescriptionHow-to-evaluate-the-microcirculation-report-of-a-round-table-conference-cc6118-S2.ogv |
English: A video clip file showing altered microcirculation in a patient with severe sepsis. Forty-nine small vessels (including four with absent flow and eight with intermittent flow) and 19 large vessels (all perfused) are visualized. MFIs for each quadrant determined clockwise from the left upper one are 3, 0, 3 and 3. Accordingly, PPV is 61%, PVD is 5.9/mm and MFI is 2.25. |
||
Date | |||
Source | De Backer D, Hollenberg S, Boerma C, Goedhart P, Büchele G, Ospina-Tascon G, Dobbe I, Ince C (2007). "How to evaluate the microcirculation: report of a round table conference". Critical Care. DOI:10.1186/cc6118. PMID 17845716. PMC: 2556744. | ||
Author | De Backer D, Hollenberg S, Boerma C, Goedhart P, Büchele G, Ospina-Tascon G, Dobbe I, Ince C | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 2.0 Generic license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 10:19, 4 December 2012 | 19 s, 1,024 × 576 (2.81 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Short title | Additional file 2 |
---|---|
Author | |
Usage terms | http://creativecommons.org/licenses/by/2.0/ |
Image title | A video clip file showing altered microcirculation in a patient with severe sepsis. Forty-nine small vessels (including four with absent flow and eight with intermittent flow) and 19 large vessels (all perfused) are visualized. MFIs for each quadrant determined clockwise from the left upper one are 3, 0, 3 and 3. Accordingly, PPV is 61%, PVD is 5.9/mm and MFI is 2.25. |
Software used | |
Date and time of digitizing | 2007 |