File:Comparison-of-Tissue-Architectural-Changes-between-Radiofrequency-Ablation-and-Cryospray-Ablation-684832.f2.ogv
From Wikimedia Commons, the free media repository
Jump to navigation
Jump to search
Size of this JPG preview of this OGG file: 799 × 338 pixels. Other resolutions: 320 × 135 pixels | 640 × 271 pixels | 1,664 × 704 pixels.
Original file (Ogg Theora video file, length 10 s, 1,664 × 704 pixels, 4.95 Mbps, file size: 5.91 MB)
File information
Structured data
Captions
Summary
[edit]DescriptionComparison-of-Tissue-Architectural-Changes-between-Radiofrequency-Ablation-and-Cryospray-Ablation-684832.f2.ogv |
English: Complete cross-sectional fly-through of the volumetric Optical Coherence Tomography images obtained immediately after the Cryospray Ablation treatment. The spongiform appearance due to the edematous tissue caused by freezing can be observed in the data set. |
||
Date | |||
Source | Tsai T, Zhou C, Lee H, Tao Y, Ahsen O, Figueiredo M, Adler D, Schmitt J, Huang Q, Fujimoto J, Mashimo H (2012). "Comparison of Tissue Architectural Changes between Radiofrequency Ablation and Cryospray Ablation in Barrett's Esophagus Using Endoscopic Three-Dimensional Optical Coherence Tomography". Gastroenterology Research and Practice. DOI:10.1155/2012/684832. PMID 22844274. PMC: 3400425. | ||
Author | Tsai T, Zhou C, Lee H, Tao Y, Ahsen O, Figueiredo M, Adler D, Schmitt J, Huang Q, Fujimoto J, Mashimo H | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 3.0 Unported license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 03:09, 15 November 2012 | 10 s, 1,664 × 704 (5.91 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Author | Tsai T, Zhou C, Lee H, Tao Y, Ahsen O, Figueiredo M, Adler D, Schmitt J, Huang Q, Fujimoto J, Mashimo H |
---|---|
Usage terms | http://creativecommons.org/licenses/by/3.0/ |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2012 |