File:WAVE2-Regulates-Epithelial-Morphology-and-Cadherin-Isoform-Switching-through-Regulation-of-Twist-pone.0064533.s011.ogv
From Wikimedia Commons, the free media repository
Jump to navigation
Jump to search
No higher resolution available.
WAVE2-Regulates-Epithelial-Morphology-and-Cadherin-Isoform-Switching-through-Regulation-of-Twist-pone.0064533.s011.ogv (Ogg Theora video file, length 2.7 s, 420 × 314 pixels, 5.83 Mbps, file size: 1.85 MB)
File information
Structured data
Captions
Summary
[edit]DescriptionWAVE2-Regulates-Epithelial-Morphology-and-Cadherin-Isoform-Switching-through-Regulation-of-Twist-pone.0064533.s011.ogv |
English: Long term live cell imaging of WAVE2-KD2 acini grown in 3D culture from day 4.5 to day 7. Movies were created from images taken every 30 minutes over a period of 2.5 days and displayed at 30 fps. The scale bar is indicated in Figure 2. |
||
Date | |||
Source | Movie S3 from Bryce N, Reynolds A, Koleske A, Weaver A (2013). "WAVE2 Regulates Epithelial Morphology and Cadherin Isoform Switching through Regulation of Twist and Abl". PLOS ONE. DOI:10.1371/journal.pone.0064533. PMID 23691243. PMC: 3654908. | ||
Author | Bryce N, Reynolds A, Koleske A, Weaver A | ||
Permission (Reusing this file) |
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 22:40, 24 May 2013 | 2.7 s, 420 × 314 (1.85 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Author | Bryce N, Reynolds A, Koleske A, Weaver A |
---|---|
Usage terms | http://creativecommons.org/licenses/by/3.0/ |
Image title | Long term live cell imaging of WAVE2-KD2 acini grown in 3D culture from day 4.5 to day 7. Movies were created from images taken every 30 minutes over a period of 2.5 days and displayed at 30 fps. The scale bar is indicated in Figure 2. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2013 |